Thanks for your contribution! Looks good to me. |
The heat meter register uses bit 0 for meter 1 and bit 1 for meter 2, but the parser tested `active & position`, so meter 1 was never reported and meter 2 showed garbage whenever meter 1 was active. Inputs of type 000 are unused according to TA's interface spec and are now returned as None instead of their raw value. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- get_value() raised KeyError because values fetched only via blnet_direct have no name; match on the id key instead - get_latest() stored the string "timeout" as a frame, which crashed fetch(), and also did so when the last retry succeeded; timed out frames are now listed in info["timeout"] and fetch() raises ConnectionError if no data arrived - BLNETDirect set the process-wide default socket timeout, and only after the first connection; the timeout is now set on its own sockets Adds a fake TCP BL-NET replaying responses recorded from a real device in DL mode, so BLNETDirect is covered by tests for the first time. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The haus-terra link to TA's interface spec returns 404, point to the archived copy instead. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Build with uv_build instead of flit_core, publish with uv build and uv publish instead of the flit action - Replace Pipfile and the test extra with a uv dev dependency group, commit uv.lock and use uv in CI - Set requires-python to >=3.8 to match CI; >=3 made uv resolve dependencies for Python 3.0 and up - Use a PEP 639 license expression so LICENSE.txt ends up in the packages, drop invalid keys readme-content-type and homepage Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Python 3.10 reached end of life on 2026-10-01, so 3.11 is the oldest supported version. Test on 3.11 to 3.15 in CI. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Enable ruff's UP rules on top of the defaults and apply their fixes: f-strings instead of format(), no coding headers, no object base class, OSError instead of its alias EnvironmentError, and no Python 2 builtins imports. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Add a copyright line for my contributions below the original notice, which stays unchanged as the MIT license requires, and list me as author in the package metadata. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- actions/checkout v4 -> v7, v4 still targets the deprecated Node.js 20 - Run the coveralls finish job with uvx instead of pip in a python container Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The PyBLNET package on PyPI belongs to upstream, this fork has no access to it. - Release workflow builds first, then creates the GitHub release with wheel and sdist attached instead of publishing to PyPI - README: drop PyPI badges, point build and coverage badges to this fork, document installing from GitHub, describe the current state of BLNet-Direct testing - Point the homepage URL to this fork and list upstream separately Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
When connecting to one of the resolved addresses failed, the socket was dropped without closing it, which Python 3.14+ reports as ResourceWarning. Only catch OSError instead of everything. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
BLNETDirect always used its default of 60 seconds, so a BL-NET that stopped answering blocked fetch() for a minute regardless of the timeout given to BLNET. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
Review the following changes in direct dependencies. Learn more about Socket for GitHub.
|
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A timeout or other error while reading left the socket open, and since _connect() only connects without a socket, every later call reused the dead connection. A BLNET object, as kept by Home Assistant, never recovered until it was recreated. - Close the socket and reset the read state on any error in get_latest, get_count, _get_data and the mode check in the constructor, which also leaked its socket on timeout - Raise ConnectionError when the BL-Net closes the connection or sends a malformed reply instead of IndexError or struct.error - Use sendall instead of send - _get_data no longer swallows errors with a return in finally Errors from the direct connection are now always OSError subclasses: ConnectionError or TimeoutError. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A real BL-Net answers GET_LATEST with a single 0xAB byte ("no data
available", see TA's interface spec) for up to about 5 seconds after a
read. The retries ran without any pause, so every read shortly after
the previous one failed with ConnectionError. Wait 2 seconds after such
a reply before the next try.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
htmldom is unmaintained and mangles parts of the BL-NET pages (button text "<=" ends up as tag fragments in the extracted text). A small html.parser based helper extracts the text of matching elements the way the value regexes expect: entities like kept as written and <br> as newline, including nested matching elements. Adds tests on the saved device pages for cases the mock server tests didn't cover (negative values, access denied page, blnet_test). They pass with both implementations, and both give identical results on all saved pages. requests is now the only runtime dependency. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Home Assistant showed every analog input in °C and speed in rpm. The parser already read the input type bits but dropped them. - BLNETParser exposes analog_types: temperature, volume_flow, radiation, digital or None for unused and undocumented types - BLNET.fetch() adds type and unit_of_measurement to analog entries from the direct connection, and type (derived from the shown unit) to entries from the web interface - speed, energy and power entries carry unit_of_measurement: None (speed is a level 0-30, not rpm), kWh and kW Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A temperature input without sensor or with a broken wire reads all value bits set, 409.5 °C, which no real sensor reaches. Return None for it like for unused inputs, so fetch() leaves it out instead of reporting 409.5 °C. Confirmed with the hydraulics chart of the recorded BL-NET: inputs 1-5 and 15 have no sensor connected. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
BL-NETs sometimes send the first byte of a GET_LATEST reply in a TCP segment of its own. _query() stopped after that byte, so the rest of the reply was read as the start of the next one and all following replies were shifted by one byte. The sum checksum accepts about one in 128 of those shifted datasets, which showed up as occasional garbage values like -3807 °C or jumps of the energy meter. Derive the reply length from its first byte and read it completely, and reconnect after a reply with a bad checksum so that stray bytes can't end up in the next reply. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01KJJTUv5YaVyYB197zeuqBp
…nus-1000-suw6ku Read GET_LATEST replies completely
|
Warning Review the following alerts detected in dependencies. According to your organization's Security Policy, it is recommended to resolve "Warn" alerts. Learn more about Socket for GitHub.
|
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01KJJTUv5YaVyYB197zeuqBp
…nus-1000-suw6ku Release 0.13.1
|
@dereisele it appears you are now maintaining your own fork of this. Are you interested in taking over maintenaince of this package? I don't have a BLNET to debug changes on my own and it seems you have one available and potent coding support :) |
|
I do have a BLNET, but I never got the CAN Bus working... Maybe you could create a GitHub Orga and ask @volkerfrank73 to join. He ported this library to async https://github.com/volkerfrank73/pyblnet-async |
|
Done! I would strongly advise to merge the repos together ultimately to prevent diverging implementations. But please feel free to maintain them now in a consistent organization. |
|
Thanks @nielstron for setting up the organization, and @dereisele for suggesting it! I'm happy to join. A bit about me: I run a UVR1611 with a BL-NET on the CAN bus and read it through the web interface and the TA port in Home Assistant, using pyblnet-async. I agree that the two implementations should be merged eventually. @nielstron, how do you imagine the collaboration going forward? And would you like to keep supporting the project, for example with reviews or PyPI releases, or would you rather hand it over completely? Right now I only have read access to the repo. If you'd like me to help maintain it, could you give me write or maintain rights? @dereisele, would you like to join as well? Your setup runs in DL mode and mine on CAN, so between us we could test both modes on real hardware, and most of the recent fixes came from you. Best regards, |
|
I am happy to hand over the project to both of you. I think I invited you both to be maintainers of this project, let me know if that's not the case. I can also add you to the pypi package as owners if needed but the current setup should work fine by you pushing new release tags. |
|
Thanks, @nielstron! I've accepted the invitation and will keep maintaining the project. Thanks for all your work on pyblnet! Best regards, |
Fix unpack in DL_MODE
Hi, I found a small bug when using the DL_MODE, since my UVR1611 has the CAN-Bus disabled.
Anyway, thanks a lot for this library