SimplePLC

A soft PLC in one small executable.
IEC 61131-3 Structured Text · Modbus TCP · OPC UA · web panel · REST API · MCP for AI agents

CI Docker pulls Image size MIT

A PLC's overview in the SimplePLC panel: the controller front with its LEDs, Running, cycle, latency and workload

Each copy of SimplePLC is one PLC: on a Raspberry Pi next to a machine, on a Linux PC or in a container. Programs are Structured Text, compiled and checked before they run. The process image is served as Modbus TCP and OPC UA, with a web panel, a REST API and an MCP server for agents. Several PLCs talk Modbus TCP to each other, and a fleet gives one panel and one agent endpoint for all of them.

  • A strict, auditable compiler. No silent narrowing, diagnostics that say how to fix the problem, and the program as compiled on request
  • Deterministic. Verified bytecode with no allocation, and the same bits on every platform (SimplePLC has its own maths functions)
  • Online change. Saving a program replaces the running one between two cycles and keeps the values of its variables
  • Safe on failure. Run-time errors stop the PLC in FAULT with the line, and outputs get their substitute values
  • Made for agents. Every operation is an MCP tool: setting up a PLC, tags, programs, forcing, logs
  • Small. One static Linux binary for x86-64, ARM64 and 32-bit Raspberry Pi OS, and an 11 MB container image

🚀 Start

Docker

The image is on Docker Hub: tommyhbe/simpleplc (linux/amd64, linux/arm64 and linux/arm/v7, so it also runs on Docker Desktop for macOS and Windows).

docker pull tommyhbe/simpleplc
docker run -p 8080:8080 -p 502:502 -p 4840:4840 -v plc1:/data tommyhbe/simpleplc

The setup code is in the container's log (docker logs <container>).

Linux and Raspberry Pi

Download the file for your machine from the latest release (x86-64, ARM64, or ARMv7 for 32-bit Raspberry Pi OS), make it executable and run it:

chmod +x simpleplc-linux-arm64 && mv simpleplc-linux-arm64 simpleplc
./simpleplc
SimplePLC 2.0.0
  Data       /home/pi/simpleplc-data
  Web panel  http://192.168.1.20:8080   (on this computer: http://localhost:8080)
  Setup code 3f1c9a2e-77b04d10   (enter it in the web panel to create your account)
  PLC        raspberrypi  Modbus :502  OPC UA :4840  [RUN]
Ready. Press Ctrl+C to stop.

Open the web panel, enter the setup code and choose a password. The PLC is named after the computer and starts empty. From there you can write a program in the editor, connect a Modbus device under I/O, or start from an example on the Overview (tank level control, traffic light, remote I/O between two PLCs, ...).

sudo simpleplc install-service makes it a system service. It then starts at every boot with nobody logged in, may use port 502, and keeps its data in /var/lib/simpleplc. Without sudo it starts at login.

🔌 Connect

Tags name addresses in the four Modbus areas (coils, discrete inputs, holding and input registers) and give each one a type: bool, int16, uint16, int32, uint32 or float32. 32-bit values take two registers, high word first. Outputs can have a substitute value, which is written at STOP and FAULT.

Client How
Modbus TCP (HMIs, Factory I/O, pymodbus, QModMaster) port 502, any unit id, addresses from 0; functions 1–6, 15, 16, 17, 22, 23 and 43/14
OPC UA (UaExpert, Ignition, Node-RED) opc.tcp://<host>:4840, security policy None; each tag is the variable ns=1;s=<tag name>; at most 100 sessions, each ending at the latest a minute after its last request
Scripts create a token under Users and tokens, then curl -H "Authorization: Bearer <token>" http://localhost:8080/api/v1/plcs
AI agents (MCP) claude mcp add --transport http simpleplc http://localhost:8080/mcp --header "Authorization: Bearer <token>"

The Communication page: a link to another PLC, the Modbus TCP and OPC UA servers with their clients, and their security

Point an agent at a device to work on its PLC, or at a fleet to work on all of them (the tools then take the PLC's id). Every PLC operation of the REST API is an MCP tool: setting a PLC up, tags, checking and deploying programs with every diagnostic, program variables, forcing, events, logs, device information, and Modbus reads and writes of any device. There are also prompts for writing a program and for building a network.

An agent can also start its own PLC, with no SimplePLC running: claude mcp add simpleplc -- simpleplc mcp --data ./lab. That PLC starts blank. Its Modbus and OPC UA listen on 127.0.0.1 only (--listen changes it), and it has no web panel unless you ask for one (--web, or --port N). docs/api.md describes the REST API, the fleet and the MCP server.

Ports below 1024 need extra rights. When port 502 cannot be used, SimplePLC takes the next free port from 5020 (OPC UA: from 4841) and says so. To use 502, run sudo setcap cap_net_bind_service=+ep ./simpleplc once. Containers can use 502 as is.

📝 Programs

(* Start the pump at or below start_level, stop it at stop_level. The level
   comes from another PLC through a link, which also sets tank_ok. *)
PROGRAM main
VAR_EXTERNAL CONSTANT
    level : REAL;          (* read by the link *)
    tank_ok : BOOL;        (* the link's status tag *)
    start_level : UINT;
    stop_level : UINT;
END_VAR
VAR_EXTERNAL
    pump_cmd : BOOL;       (* sent to the pump by the link; substitute value FALSE *)
END_VAR
    IF NOT tank_ok THEN
        pump_cmd := FALSE;             (* no level, no pump *)
    ELSIF level <= start_level THEN
        pump_cmd := TRUE;
    ELSIF level >= stop_level THEN
        pump_cmd := FALSE;
    END_IF;
END_PROGRAM

A program declares the tags it uses in VAR_EXTERNAL (CONSTANT for the ones it only reads) and keeps its state in VAR. The standard timers, edge detectors, counters and functions are all available.

  • Strict compiler. No silent narrowing (INT := DINT needs a conversion), no a < b < c, and every diagnostic says how to fix the problem. simpleplc check main.st --tags tags.json --listing prints the problems and the program as compiled, with every conversion and parenthesis written out.
  • Runs as verified bytecode with no allocation. A run-time error (overflow, division by zero, an index out of range) stops the PLC in FAULT with the line, and tags with a substitute value get it.
  • Online change. Saving a changed program replaces the running one between two cycles and keeps the values of the variables that still exist. A program that doesn't compile is refused, and the running one carries on.
  • Same results everywhere. A program gives the same bits on every platform, because the maths functions are SimplePLC's own.

The reference is the panel's Help page and docs/structured-text.md. docs/st-compliance.md states what is implemented and how.

The program editor with live values of tags and variables next to the code

🏭 A network of PLCs

Several PLCs are several SimplePLCs: processes, containers or Raspberry Pis that talk Modbus TCP. A link in a PLC's configuration makes it a Modbus TCP client of another device. The link says which of its tags to read from which addresses, which to write, how often, and which status tag is TRUE while the device answers. Programs only use tags, and every PLC is a Modbus TCP server to whoever polls it.

Two PLCs and a fleet on one Docker network (on Raspberry Pis, give --device their addresses instead):

export SIMPLEPLC_TOKEN=$(openssl rand -hex 16)
docker network create plant
docker run -d --name tank --hostname tank --network plant -e SIMPLEPLC_TOKEN \
    -e SIMPLEPLC_EXAMPLE=tank tommyhbe/simpleplc
docker run -d --name alarms --hostname alarms --network plant -e SIMPLEPLC_TOKEN \
    -e SIMPLEPLC_EXAMPLE=remote-io tommyhbe/simpleplc
docker run -d --name fleet --network plant -p 127.0.0.1:8080:8080 -e SIMPLEPLC_TOKEN \
    -e SIMPLEPLC_DEVICES=tank,alarms tommyhbe/simpleplc fleet

alarms runs the remote-io example. Its link reads tank's level every 200 ms, and its program raises an alarm above a limit. The fleet shows the PLCs of many devices on one panel, with their links, and gives agents one MCP endpoint for all of them. It can also start without devices and adopt them with a pairing code (docs/api.md, "The fleet").

A fleet of three PLCs, all running, with their cycle, links and version The same fleet with the pump controller in FAULT: division by zero at main.st line 47
Three PLCs in one fleet A fault shows where it happened

⚙️ Settings

Everything lives in one data directory: ./simpleplc-data, or ~/.simpleplc when the current directory is not writable, and /data in the container. One process uses it at a time.

config.json          web port, log level and the PLC: id, name, tags, tasks, links, ports
users.json           users and API tokens (hashed)
programs/<name>.st   programs and libraries (1 MB each, 2 MB together); .history/ keeps earlier versions,
                     .deployed/ the files each program last loaded with (what a restart runs, never a draft)
mode                 run or stop, as last commanded on the panel or the API: the PLC powers up in it

The panel edits all of it.

  • Tasks and links: a PLC has up to 8 tasks (cycle_ms 1–60000) and 16 links. realtime gives tasks with a priority real-time scheduling (SCHED_FIFO).
  • Retentive memory: tags with "retain": true and RETAIN variables are written to retain.json when they change, at most once a second, and come back after a power cut. Every other tag starts at 0, and every other variable starts from its initial value.
  • Mode: the commanded mode is kept too, so a PLC in STOP comes back in STOP.

A new data directory starts from these flags or environment variables. An existing one keeps its configuration and says so.

Flag Environment Default
--id SIMPLEPLC_ID the host name (a container's hostname)
--name SIMPLEPLC_NAME the example's title, or the id
--example SIMPLEPLC_EXAMPLE none: a blank PLC; or tank, blink, traffic-light, remote-io, factory-io-conveyor, temperature-pid
--modbus-port, --opcua-port SIMPLEPLC_MODBUS_PORT, SIMPLEPLC_OPCUA_PORT 502, 4840
--listen every interface (simpleplc mcp: 127.0.0.1); on the first run it applies to Modbus and OPC UA too
simpleplc [--data DIR] [--port N] [--listen ADDR] [-v | -q] [--log-json]
simpleplc fleet --device URL ...             one panel and MCP endpoint for the PLCs of many devices
simpleplc mcp [--data DIR] [--web]           MCP on stdin/stdout with its own PLC
simpleplc mcp --url URL --token TOKEN        MCP on stdin/stdout for a running SimplePLC or fleet
simpleplc check FILE.st ... [--tags FILE] [--listing]    compile and print every problem
simpleplc install-service                    run at login; with sudo: a system service at boot
simpleplc --version | --help

--data and --port also come from SIMPLEPLC_DATA and SIMPLEPLC_WEB_PORT. SIMPLEPLC_TOKEN is an administrator token for scripts, agents and fleets, and is never stored. A fleet signs in to its --device devices with SIMPLEPLC_DEVICE_TOKEN (default: its own SIMPLEPLC_TOKEN).

🔒 Security

Warning

Modbus TCP has no authentication, and OPC UA runs with security policy None (no encryption, no signing). Anyone who can reach those ports can read and write the PLC.

  • Network: keep PLCs on a network you trust, or set their listen addresses to 127.0.0.1 in Settings. The network example above publishes only the fleet's panel, on 127.0.0.1.
  • Panel and API: they need a login or a token, but are served over plain HTTP.
  • Programs: they have no file, process or network access. They read and write their tags, and the bytecode is verified before it runs.
  • Fleet: a fleet holds an administrator token for every device, so treat it like the engineering station it is.

🛠️ Build from source

You need a C++23 compiler (GCC 13 or later, or Clang 19 or later) and CMake 3.24. cmake -B build && cmake --build build -j builds ./build/simpleplc.

  • open62541: an installed open62541 1.4+ is used when found. Otherwise (or with -DSIMPLEPLC_FETCH_OPEN62541=ON), open62541 1.5.9 is built from source, which needs Python 3 and Git.
  • Static builds: -DSIMPLEPLC_STATIC=ON links statically (with musl, as the releases do). The Dockerfile builds the same static binary for any platform Docker can build for.

License

MIT, see LICENSE. Bundled components and their licences are listed in THIRD_PARTY_LICENSES.md.