38 changes: 38 additions & 0 deletions src/content/docs/en/_intros/_meters.mdx
Original file line number Diff line number Diff line change
Expand Up @@ -22,3 +22,41 @@ In that case you reference the same device at every relevant role.
## Features \{#features\}

<FeatureList keys={["battery-control", "dim", "curtail"]} />

## Indevolt \{#indevolt-configuration\}

Choose the template for your hardware model:

- `indevolt-hybrid`: models with direct solar inputs and additional solar measurements, even when no panels are connected.
- `indevolt-battery`: Eco/AC models without direct solar inputs. Eco also denotes an AC-coupled variant.

`indevolt-battery` already supports active battery control.
[PR #36194](https://github.com/evcc-io/evcc/pull/36194) adds control for hybrid models and checks write acknowledgements for both templates.
The PR has not been merged; the hybrid control settings below require a build of this PR.

For `usage: battery`, control is then available without an additional `controllable` parameter, including for existing configurations.
Solar and grid meter usages remain read-only.
Optional `maxchargepower` sets grid charging power: 1200 W by default for hybrid models and 2400 W for Eco/AC.
Adjust it to a charging power your device supports.
`minsoc` and `maxsoc` remain optional with defaults of 0 % and 100 %; use your battery system's limits.

```yaml
meters:
- name: battery
type: template
template: indevolt-hybrid
usage: battery
host: indevolt.local
maxchargepower: 1200
```

| Mode | Behaviour |
| -------- | --------------------------------------------------------- |
| `normal` | Disable grid charging and select self-consumption mode |
| `hold` | Standby: prevents discharge and also stops solar charging |
| `charge` | Grid charging at `maxchargepower` towards `maxsoc` |

An acknowledgement with boolean `result: true` confirms that the device accepted the command; check its actual state separately.
Rejected or malformed responses stop the command sequence without rolling back earlier steps.
The next control cycle reapplies the current request, including `normal` if a charge request has ended.
This does not retry immediately or read back the physical mode.