Skip to content

fix: advertise mu-mpc phase C to A voltage as measured in reference to phase A - #263

Open
sthelen-enqs wants to merge 1 commit into
devfrom
fix/mu-mpc-phase-c-to-a-voltage
Open

sthelen-enqs wants to merge 1 commit into
devfrom
fix/mu-mpc-phase-c-to-a-voltage

Conversation

@sthelen-enqs

Copy link
Copy Markdown
Contributor

MPC-041/6 defines the phase to phase voltage between phase C and phase A (acMeasuredPhases "c", acMeasuredInReferenceTo "a"). The "ac" key was split into "a" in reference to "c" instead.

…se A

MPC-041/6 defines the phase to phase voltage between phase C and phase A
(acMeasuredPhases "c", acMeasuredInReferenceTo "a"). The "ac" key was
split into "a" in reference to "c" instead.
@sthelen-enqs sthelen-enqs self-assigned this Oct 23, 2026
@sthelen-enqs

Copy link
Copy Markdown
Contributor Author

This has been ACK'd through independent testing. Will merge in a few days if there are no comments

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant