11 changes: 9 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -142,8 +142,15 @@ the profile capability are recorded and capped before a frequency is chosen.
Mode changes ramp the compressor to zero before restarting in the other mode.

Pump writes control a settling flow model and the flowswitch. `2138` uses the
OpenQuatt conversion `round(flow_lph / 0.618)`. Water-out temperature follows
the simulated thermal power and mass flow through a first-order response.
OpenQuatt conversion `round(flow_lph / 0.618)`. Water-out temperature follows a
finite water heat capacity and the heat carried away by the flow. The existing
four-second response setting defines that capacity at 800 l/h; it is a simulator
parameter, not a measured ODU water volume. At zero flow, remaining compressor
power heats the trapped water at a finite rate instead of dividing by nearly
zero flow. After the compressor stops, trapped water retains its heat until flow
resumes; heat loss to the surroundings is not modelled. With steady flow, the
final temperature difference still corresponds to thermal power divided by
water mass flow and specific heat capacity.
`ODU external system pump flow` applies the configured iPWM flow without
requiring ODU pump-relay register `2010`; use it when the controller drives a
separate system pump. Water-in can be set from 0.0 to 60.0 °C in 0.1 °C steps.
Expand Down
21 changes: 14 additions & 7 deletions components/quatt_odu_simulator/quatt_odu_simulator_model.h
Original file line number Diff line number Diff line change
Expand Up @@ -840,15 +840,22 @@ class QuattOduSimulatorModel {
this->state_.ac_current_a =
this->state_.electrical_power_w / std::max(1.0f, this->state_.ac_voltage_v * this->settings_.power_factor);

float target_out = this->state_.water_in_temperature_c;
if (this->state_.flow_lph > 1.0f && this->state_.thermal_power_w > 0.0f) {
const float delta = this->state_.thermal_power_w / ((this->state_.flow_lph / 3600.0f) * 4180.0f);
// A finite water volume prevents P/flow from diverging during a pump stop.
// Calibrate the existing response time at the default 800 L/h operating point;
// this is a simulator calibration, not a measured ODU water volume.
const double capacity_j_per_k = 4180.0 * (800.0 / 3600.0) * this->settings_.water_response_tau_s;
if (std::isfinite(capacity_j_per_k) && capacity_j_per_k > 0.0f) {
const double conductance_w_per_k = 4180.0 * (this->state_.flow_lph / 3600.0);
const float sign = this->state_.active_mode == WorkingMode::COOLING ? -1.0f : 1.0f;
target_out += sign * delta;
if (this->state_.defrost_active()) target_out -= 4.0f;
float heat_w = sign * this->state_.thermal_power_w;
if (this->state_.defrost_active() && this->state_.thermal_power_w > 0.0f)
heat_w -= 4.0f * conductance_w_per_k;
const double a = conductance_w_per_k * dt_s / capacity_j_per_k;
const double alpha = -std::expm1(-a);
this->state_.water_out_temperature_c +=
(this->state_.water_in_temperature_c - this->state_.water_out_temperature_c) * alpha +
heat_w * dt_s / capacity_j_per_k * (a > 0.0f ? alpha / a : 1.0f);
}
this->state_.water_out_temperature_c += (target_out - this->state_.water_out_temperature_c) *
std::clamp(dt_s / this->settings_.water_response_tau_s, 0.0f, 1.0f);
this->state_.condensing_temperature_c =
this->state_.water_out_temperature_c + 5.0f + this->state_.measured_frequency_hz * 0.03f;
this->state_.evaporating_temperature_c =
Expand Down
88 changes: 88 additions & 0 deletions tests/quatt_odu_water_capacity_test.cpp
Original file line number Diff line number Diff line change
@@ -0,0 +1,88 @@
#include <cassert>
#include <cmath>
#include <cstdio>
#include "../components/quatt_odu_simulator/quatt_odu_simulator_model.h"
using namespace esphome::quatt_odu_simulator;
constexpr float kCapacity = 4180.0f * 800.0f / 3600.0f * 4.0f;
QuattOduSimulatorModel steady(float flow, float frequency = 0.0f, WorkingMode mode = WorkingMode::HEATING) {
QuattOduSimulatorModel m;
m.configure(Profile::V1_5);
m.mutable_settings().flow_offset_lph = flow;
m.mutable_settings().flow_gain_lph_per_ipwm = 0.0f;
m.mutable_settings().freeze_measured_frequency = true;
m.mutable_state().force_flow_without_relay = true;
m.mutable_state().flow_lph = flow;
m.mutable_state().measured_frequency_hz = frequency;
m.mutable_state().active_mode = m.mutable_state().requested_mode = mode;
return m;
}
int main() {
// Independent analytic cooling solution; subdivision must not change it.
for (float step : {0.25f, 1.0f, 2.0f}) {
auto m = steady(800.0f);
m.mutable_state().water_out_temperature_c = 50.0f;
for (int i = 0; i < static_cast<int>(20.0f / step); ++i)
m.update(step);
assert(std::fabs(m.state().water_out_temperature_c - (30.0f + 20.0f * std::exp(-5.0f))) < 0.0001f);
}
// Closed water retains heat after the compressor stops.
auto trapped = steady(0.0f);
trapped.mutable_state().water_out_temperature_c = 50.0f;
for (int i = 0; i < 20; ++i)
trapped.update(1.0f);
assert(trapped.state().water_out_temperature_c == 50.0f);
// No discontinuity at the former 1 L/h cutoff; zero-flow input is energy bounded.
float previous = 0.0f;
for (float flow : {0.0f, 0.99f, 1.0f, 1.01f}) {
auto m = steady(flow, 50.0f);
m.update(0.25f);
const float rise = m.state().water_out_temperature_c - 30.0f;
assert(rise > 0.0f && rise <= m.state().thermal_power_w * 0.25f / kCapacity + 0.00001f);
if (flow > 0.0f)
assert(std::fabs(rise - previous) < 0.001f);
previous = rise;
}
// Heating, cooling and defrost retain the stationary calorimetric balance.
for (int scenario = 0; scenario < 3; ++scenario) {
auto m = steady(800.0f, 50.0f, scenario == 1 ? WorkingMode::COOLING : WorkingMode::HEATING);
if (scenario == 2)
m.set_defrost(true);
for (int i = 0; i < 800; ++i)
m.update(0.25f);
const float conductance = 4180.0f * 800.0f / 3600.0f;
const float expected =
(scenario == 1 ? -1.0f : 1.0f) * m.state().thermal_power_w - (scenario == 2 ? 4.0f * conductance : 0.0f);
assert(std::fabs(conductance * (m.state().water_out_temperature_c - 30.0f) - expected) < 0.1f);
}
// Pump-stop sequence cannot add more heat than the simulated compressor delivered.
QuattOduSimulatorModel m;
m.configure(Profile::V1_5);
m.mutable_settings().compressor_start_delay_s = m.mutable_settings().minimum_runtime_s = 0.0f;
m.write_register(1999, 8, 1);
m.write_register(3999, 2, 2);
m.write_register(2010, 4096, 3);
m.write_register(2015, 150, 4);
for (int i = 0; i < 120; ++i)
m.update(0.25f);
const float start = m.state().water_out_temperature_c;
float energy_j = 0.0f;
m.write_register(2015, 1000, 5);
for (int i = 0; i < 80; ++i) {
m.update(0.25f);
energy_j += m.state().thermal_power_w * 0.25f;
assert(std::isfinite(m.state().water_out_temperature_c));
assert(m.state().water_out_temperature_c <= start + energy_j / kCapacity + 0.001f);
}
auto invalid = steady(0.0f, 50.0f);
invalid.mutable_settings().water_response_tau_s = 0.0f;
invalid.update(1.0f);
assert(invalid.state().water_out_temperature_c == 30.0f);
// A tiny finite capacity reaches equilibrium without overflowing intermediates.
auto tiny = steady(800.0f, 50.0f);
tiny.mutable_settings().water_response_tau_s = 1e-40f;
tiny.update(0.25f);
const float equilibrium = 30.0f + tiny.state().thermal_power_w / (4180.0f * 800.0f / 3600.0f);
assert(std::isfinite(tiny.state().water_out_temperature_c));
assert(std::fabs(tiny.state().water_out_temperature_c - equilibrium) < 0.0001f);
std::puts("Finite water capacity tests passed");
}
Loading