Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
De gecombineerde simulator heeft al een forced-defrostpad, maar
3999=4startte ook zonder actuele verwarmingsvoorwaarden en herhaalde writes verlengden de timer. Deze wijziging publiceertmanual-defrost-v1, maakt herhaalde aanvragen idempotent en geeft per ODUstarted/completed/aborted-tellers voor de HIL-scenario’s in OpenQuatt/OpenQuatt#761.De v0.5.0-fixture duurt standaard 30 seconden (instelbaar 1..600). Start vereist werkelijk gesimuleerd verwarmen, compressorfeedback, flow switch en ≥250 l/h, foutvrije registers en geen manual override/injectie. Mode4, defrostbit, vierwegklep en bodemplaatheater worden zichtbaar. Normale afloop telt één completion; stop of verloren voorwaarden telt één abort. Generieke diagnostiekreset wist de cyclustellers niet; boot/modelreconfiguratie wel. Bestaande injecties blijven apart. Het basiscontract blijft
openquatt-modbus-opentherm-v2.Validatie:
-std=c++17 -Wall -Wextra -Werror, inclusief alle vier profielen, 249/250, duplicate timer, completion, stop/abort, fault words, manual override, heater en diagnostic reset.python3 scripts/generate_odu_contract.py --checkengit diff --checkgeslaagd.esphome config hcq_v1_boiler_simulator.yamlenesphome compile hcq_v1_system_simulator.yamlgeslaagd. Firmware config hash0xb51a3051.Naar de desktop-simulator geüpload na expliciete OTA-toestemming. Runtime-capability en fysieke cyclus zijn gecontroleerd met OpenQuatt/OpenQuatt#761. Dit is een versnelde control-pathfixture, geen validatie van echte ODU-algoritmen, hydrauliek of defrostduur.
GitHub CI op
76653b34: geslaagd, inclusief host-tests en gecombineerde ESPHome-firmwarecompile.Fysieke desktop-HIL op 27 september 2026: simulator v0.5.0 (
manual-defrost-v1, firmware hash0xb51a3051) en OpenQuatt-kandidaat0xf78b6c5e. Alle vier defrostgevallen PASS: peer-overlap geweigerd zonder start, geselecteerde flow 249 l/h geweigerd, 250 l/h geaccepteerd, één completed cycle. HP1started=1 completed=1 aborted=0; HP20/0/0. Verse mode4/defrostbit/vierwegklep/heater-readbacks vereist, daarna terug naar heating/bit clear/COMPLETE en 30s stabiel herstel zonder boilerfallback of tweede cyclus. Beide ODU’s vervolgens bevestigd gestopt; normale guards bleven intact. Modbus exc/bad_addr/bad_write/cap=0.Bewijs in de OpenQuatt-checkout:
.tmp/hil/2026-09-27T07-15-52-234Z-defrost/report.json, 54 defrost- en 286 control-observaties, snapshot en controllerlogstream. Eindbewijs.tmp/hil/pr761-defrost-upload/final-state.json: simulator v0.5.0 blijft geïnstalleerd met beide actieve profielen V1.5, injecties uit. Oorspronkelijke controllerfirmware/settings en run extension hersteld; beide peers healthy/stopped, ketel uit en lablock vrij. De voorafgaande controle tijdens profielreboot wachtte terecht op vers linkherstel en telt niet als productiebug of PASS-case.