12 changes: 9 additions & 3 deletions skills/hcq-hil/SKILL.md
Original file line number Diff line number Diff line change
Expand Up @@ -103,13 +103,12 @@ controller exposes independent UART-fault evidence.
simulator input entities in [the REST reference](references/esphome-rest.md)
to vary room temperature, room setpoint, `TSet`, boiler telemetry or ODU
water input. Read the allowed range, set one controlled value, verify the
controller outcome and restore the prior value. Do not conflate simulated
controller outcome. Do not conflate simulated
boiler telemetry with a physical PT1000 supply-sensor test.
- Treat the testcontroller's input-source selection as part of the test state.
Read the controller source selectors and use its verified `api_input_*` HTTP
endpoints for controller-side room, outdoor, dew-point, demand and enable
scenarios. Verify source selection and freshness after every write, then
restore the previous source and input state. The current API-input surface
scenarios. Verify source selection and freshness after every write. The current API-input surface
has no water-supply-temperature input; do not substitute another sensor or
claim a supply-temperature API test.
- Check the actual behavior and relevant counters; do not treat a successful
Expand All @@ -123,6 +122,13 @@ controller exposes independent UART-fault evidence.
the final simulator state with the result instead.
- Still leave an active fault injection disabled: use the fault helper or turn
its switch off before ending the current run.
- Do not restore ordinary testcontroller settings, input-source selections or
API-input values after a HIL run unless the user or scenario requests it.
Each new test uploads its own firmware and establishes its own test state.
Firmware uploads can preserve settings, so explicitly set and verify the
inputs and selectors needed by each scenario rather than assuming defaults.
Record relevant final controller settings with the result; restore a value
within a run only when a subsequent assertion needs that baseline.
- For a normal “test deze PR”-request, run the read-only smoke test directly.
Ask one concise question only if the relevant test needs OTA/flash, reboot,
fault injection, a change outside the requested diff, or an action that
Expand Down
4 changes: 3 additions & 1 deletion skills/hcq-hil/references/esphome-rest.md
Original file line number Diff line number Diff line change
Expand Up @@ -102,7 +102,9 @@ curl -fsS 'http://openquatt-test.local/select/Room%20Setpoint%20Source?detail=al

Use `POST -H 'Content-Length: 0'` and follow every write with a GET. Select
`API input` on the matching controller source before interpreting the control
result, then restore the prior source and input state after the test. Example:
result. Leave ordinary source selections and input values in place after the
test; record them and explicitly establish the next scenario's required state.
Do not assume that a firmware upload clears persisted settings. Example:

```sh
curl -fsS -X POST -H 'Content-Length: 0' \
Expand Down
Loading